Construction Materials |
Jacket Material |
PE |
Outer Conductor Material |
Corrugated copper |
Dielectric Material |
Foam PE |
Flexibility |
Standard |
Inner Conductor Material |
Corrugated copper tube |
Jacket Color |
Black |
|
Dimensions |
Nominal Size |
1-5/8 in |
Cable Weight |
0.70 lb/ft | 1.00 kg/m |
Diameter Over Dielectric |
44.450 mm | 1.750 in |
Diameter Over Jacket |
51.054 mm | 2.010 in |
Inner Conductor OD |
18.1610 mm | 0.7150 in |
Outer Conductor OD |
46.355 mm | 1.825 in |
|
Electrical Specifications |
Cable Impedance |
50 ohm ±1 ohm |
Capacitance |
22.0 pF/ft | 72.2 pF/m |
dc Resistance, Inner Conductor |
0.410 ohms/kft | 1.435 ohms/km |
dc Resistance, Outer Conductor |
0.160 ohms/kft | 0.525 ohms/km |
dc Test Voltage |
15000 V |
Inductance |
0.187 µH/m | 0.057 µH/ft |
Insulation Resistance |
100000 Mohms•km |
Jacket Spark Test Voltage (rms) |
10000 V |
Operating Frequency Band |
1 – 2700 MHz |
Peak Power |
302.0 kW |
Pulse Reflection |
0.5% |
Velocity |
92% |
|
Environmental Specifications |
Installation Temperature |
-40 °C to +60 °C (-40 °F to +140 °F) |
Operating Temperature |
-55 °C to +85 °C (-67 °F to +185 °F) |
Storage Temperature |
-70 °C to +85 °C (-94 °F to +185 °F) |
|
General Specifications |
Brand |
HELIAX® |
|
Mechanical Specifications |
Bending Moment |
47.5 N-m | 35.0 ft lb |
Flat Plate Crush Strength |
90.0 lb/in | 1.6 kg/mm |
Minimum Bend Radius, Multiple Bends |
381.00 mm | 15.00 in |
Minimum Bend Radius, Single Bend |
203.20 mm | 8.00 in |
Number of Bends, minimum |
15 |
Number of Bends, typical |
50 |
Tensile Strength |
181 kg | 400 lb |
|
Note |
Performance Note |
Values typical, unless otherwise stated |
|
Standard Conditions |
Attenuation, Ambient Temperature |
20 °C | 68 °F |
Average Power, Ambient Temperature |
40 °C | 104 °F |
Average Power, Inner Conductor Temperature |
100 °C | 212 °F |